Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Guides / Pumps & Controls

FTI Mag-Drive Pumps

The Zero-Leak Standard for Chemical Transfer

Sealless magnetic drive designs eliminate the mechanical seal — the #1 cause of pump downtime. From flooded suction to deep-lift self-priming and ANSI-dimensional pumps, FTI delivers leak-proof, emission-free performance for corrosive and hazardous chemicals.

Direct answer: FTI mag-drive pumps use a sealless magnetic drive design that eliminates the mechanical seal — the #1 cause of pump downtime — for zero-emission, leak-free transfer of corrosive and hazardous chemicals. The lineup ranges from flooded-suction (DB) and self-priming (SP) models up to ANSI-dimensional pumps (UCR) rated to 492 ft of head, 300 psi, and 250°F, so the right series depends on flow, head, viscosity, and chemical service.

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →
Zero
Emissions & Leakage
25 ft
Self-Priming Lift (SP)
300 psi
Max Pressure (UCR/UCP)
492 ft
Max Head (UCR)
The James Factor

Doing It Yourself vs. Specifying With James Riggins

FactorDoing It YourselfWith James Riggins
Pump Selection & NPSH Check10–24 hrs2–4 hrs (60–80% saved)
Startup & Commissioning2–3 days troubleshooting< 1 day with correct curve & materials
Chemical CompatibilityRisk of mis-specVerified PP/PVDF/ETFE lining
Maintenance DowntimeSeal failures & leaksSealless magnetic drive reliability
Product Lineup

The FTI Mag-Drive Pump Lineup

DB Series (Flooded Suction)

<1–221 GPM · 20–201 ft / 90 psi · >150 cP · PP 180°F / PVDF 220°F · Highest efficiency in class (to 70%)

SP Series (Self-Priming)

<1–253 GPM · 20–221 ft / 90 psi · >50 cP · Lift: 25 ft (7.6 m); primes 18 ft in 90 sec

MSDB Series (Multi-Stage)

1–69.8 GPM · 204–306 ft / 135 psi · >150 cP · PP/PPS 180°F / PVDF/PPS 220°F · High-head, low-flow filtration/spray

KC / MSKC Series (Compact Multi-Stage)

to 60 GPM · to 100 ft / 80 psi · to 100 cP · Compact multi-stage, small footprint

UCR Series (ANSI Dimensional)

1–1450 GPM · to 492 ft / 300 psi · >200 cP · Max Temp 250°F · Ductile iron with pure ETFE barrier & lining

UCP Series (ANSI Dimensional, PP/ETFE)

to 450 GPM · to 330 ft / 300 psi · >200 cP · Max Temp 180°F · Pure, unfilled PP barrier + reinforced shell

UC Legacy Series (Original ULTRAChem®)

Tough ductile iron with ETFE lining · ANSI dimensional, sealless mag-drive · Extreme corrosion protection & leak-free duty

Blue Finish Thompson MSDB sealless mag-drive pump on a concrete pad, flooded suction from a 12.5% sodium hypochlorite day tank
Finish Thompson MSDB

Finish Thompson MSDB: multistage sealless mag-drive for high head, low flow

The MSDB is Finish Thompson's multistage sealless mag-drive pump for high-head, low-flow chemical duty. Built on the DB11/15 platform, the MSDB2 (2-stage) reaches about 204 ft and the MSDB3 (3-stage) about 306 ft at 60 Hz, both near 70 gpm maximum, with a 135 psi pressure limit. Wetted materials are polypropylene/PPS (to 180°F) or PVDF/PPS (to 220°F).

It is not self-priming: install it on a flooded suction and keep NPSH available at least 2 ft above NPSH required. With a carbon bushing it tolerates occasional dry running; PTFE, ceramic and silicon-carbide bushings cannot run dry, and Finish Thompson still recommends a power monitor.

Free Finish Thompson Tools

Size it right before you buy

Pump review checklist to complete before installing a sealless mag-drive pump on chemical service
Free PDF · Mag-drive pumps
Mag-Drive Run-Dry & Suction Checklist

The Finish Thompson MSDB pump-review checklist: carbon-bushing run-dry limits, NPSH margin and the suction-piping rules that decide pump life.

Get the checklist →
FT30P diaphragm pump with its compressed-air filter-regulator and pressure gauge mounted on the skid frame, blue air line feeding the center section
Free tool + PDF · AODD pumps
Diaphragm Pump Sizing Calculator

Enter flow, head, SG and plant air. See the air pressure and SCFM your duty needs on a real FTI Air FT30P curve, then get the worksheet by email.

Check your duty point →
FAQ

Frequently Asked Questions

Why choose a sealless mag-drive pump over a traditional sealed pump?

Sealless magnetic drive designs eliminate the mechanical seal — the #1 cause of pump downtime — providing zero-emission, leak-free performance for corrosive and hazardous chemicals.

What's the difference between the DB and SP series?

DB Series is a flooded-suction design with the highest efficiency in its class (up to 70%), while SP Series adds self-priming capability with a 25 ft lift and 18 ft prime in 90 seconds.

What temperature and pressure can UCR series pumps handle?

UCR Series (ANSI-dimensional, ductile iron with pure ETFE lining) handles up to 492 ft of head / 300 psi and up to 250°F, the highest-rated series in the FTI mag-drive lineup.

Spec Review

Get this spec'd right the first time

Send LibertyCES your process conditions — James matches technology, materials, and controls to your exact application.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · james@libertyces.com.

Related

Related Guides & Products

Fluid Transfer & Pump Products →Chemical Metering Pump Failure Guide →Chemical Pumps Failure Guide →