LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — No sales queue. Real engineering answers.
Chemical Compatibility

PFA/PTFE-Lined Valve & Sight Glass — Hydrocarbons/Fuels/Oils

Moderate evidence

Named chemicals

Freon-11Freon-12Freon-21Freon-22Freon-113Freon-114creosotetall oilolive oil (hot)

What LibertyCES's vendor documentation shows

The specific finding a fluoropolymer-lined equipment page should lead with: across all six refrigerants in the Flowline chart, PVDF/PFA/PTFE all rate E while 316SS drops to F — the only family in the 552-row chart where stainless is the weakest listed wetted material against an otherwise benign-looking fluid. Same pattern, less severe, on creosote and tall oil. Moderate because no vendor page in the corpus names Freon service directly; the material conclusion is from the chart and the lined products above are the corpus's matching hardware.

Materials documented for this service

  • PFA lining
  • PTFE
  • Borosilicate glass panes to DIN 7080
  • Housing EN-JS 1049
  • Flowline chart, all six Freons at 40°C/104°F: PVDF E, PFA E, PTFE E — but 316SS only F (Fair)
  • Flowline chart: 316SS G on creosote and tall oil at both 40°C and 80°C; F on olive oil at 80°C

Products cited for this service

Richter PSG/F and PSG/F-L sight glasses (PFA and antistatic PFA, DN25-DN150, 16 bar, -60°C to +180°C)Richter TSG/F and TSG/F-L (DN25-DN80)Richter SGS/F and SGS/F-L (DN15-DN100, 6 bar, cylindrical, cavity-free option)Richter MV/MVP PFA-lined diaphragm valveRichter PA/F PFA-lined sampling valve (cavity-free, DN25-DN80, 16 bar, -60°C to +200°C)Richter BAV/BAVM bottom drain stem valve (thick-walled vacuum-proof PTFE lining, DN80/50-DN150/100, 10 bar)

Sourced to

  • data/reference/flowline-chemical-compatibility.csv
  • data/vendor-sources/richter-ct-sight-glasses.md
  • data/vendor-sources/richter-ct-sliding-stem-valves.md
  • data/vendor-sources/crane-cpe-xomox-sleeved-plug-valves.md

Every material and product claim on this page traces to the vendor documentation listed above. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.