Chemical Compatibility

Temperature Sensor — Metal Plating & Photographic Process Solutions

Strong evidence

Named chemicals

plating bath solutionschromic acidnickel sulfateeffluent from plating rinse

What LibertyCES's vendor documentation shows

Plating Bath Temperature Control is the first-listed application on Signet's own 2350 page. The material argument is unusually clean: the PVDF body 'outlasts metal sensors in aggressive liquids and eliminates the need for costly custom thermowells' — the sensor body IS the corrosion barrier, so there is no metal thermowell for chromic acid to attack. Pair with the chart finding that 316SS rates only C on chromic acid at every concentration and the case for a non-metallic temperature sensor in a plating line makes itself.

Materials documented for this service

  • PVDF one-piece body (replaces a metal thermowell entirely)
  • Pt1000 platinum RTD element
  • In-line mounting 100°C @ 7.5 bar / 108 psi; submersible mounting 85°C @ 7.5 bar — a real lower ceiling for submersible use

Products cited for this service

GF Signet 2350 Temperature Sensor (one-piece injection molded PVDF body, Pt1000 platinum RTD in an extended tip, factory calibrated 0-100°C / 32-212°F for 4-20mA, digital S3L accuracy ±0.5°C with 0.01°C resolution and 10-second response, 3/4in NPT male both ends)

Sourced to

  • data/vendor-sources/gf-signet-instrumentation-catalog.md

Every material and product claim on this page traces to the vendor documentation listed above. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.