Chemical Compatibility

Storage Tank — Oxidizers/Disinfectants

Strong evidence

Named chemicals

Sodium HypochloriteHydrogen Peroxide

What LibertyCES's vendor documentation shows

Poly Processing caps on-site hypochlorite generation (0.8%) at 4,000 gallons without engineering review; hinged-weighted manway vents at 0.25psi for H2O2 decomposition.

Materials documented for this service

  • EPDM (fails per Ace Roto-Mold: flat 'N')
  • 316SS (fails: flat 'N')
  • dedicated resin #880059 (Snyder)

Products cited for this service

Snyder Vertical/Horizontal/Chemical Feed Station tanksAce Roto-Mold Vertical TanksPeabody ProChem (hinged-weighted manway for H2O2)

Sourced to

  • ace-roto-mold-application-guidelines.md
  • snyder-industries-tanks.md
  • poly-processing-fittings-accessories.md
  • peabody-general-catalog.md

Every material and product claim on this page traces to the vendor documentation listed above. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.